Our Service Areas

Gas Tankless Hot Water Heaters

Tankless hot water heaters from have become very popular in Culver, IN. Unlike conventional water tanks that make and store hot water 24 hours per day, tankless water heaters produce hot water as you are using it and shut down when you are done. A typical homeowner or business in Culver, IN can expect substantial energy savings. In addition, gas tankless units never run out of hot water so they are extremely convenient. Enjoy high efficiency, energy savings and endless hot water with a tankless system.

Get Your Quote Today

Estimated To Replace Electric Tank Water Heaters With High Efficiency On Demand Tankless Water Heaters By Navien. Includes Gas Pipe,venting,and Drains.
Carol, D. Culver , IN
04-10-2024
Quote To Install Navien On Demand Tankless Water Heater. Including Main Power,gas Line , Venting,condensation Drain, And Recirculating Loop.
Judy, B. Culver , IN
04-01-2024
Quotes For Navien Tankless Water Heater , 2 New ADA Elongated Toilets And 2 New Frost Free Hydrants. Was Able To Quote, Explain Options, Invoice, And Schedule Job During One Visit.
James , B. Culver, IN
03-13-2024
Navien NPE-210S
Installed Two Navien Tankless Water Heaters
Mike, G. Culver , IN
12-21-2023
Navien NPE-210S
Installed Two Navien Tankless Water Heaters
Mike, G. Culver , IN
12-21-2023
Navien NPE-240A
Navien Tankless High Efficiency On Demand Water Heater Quoted For Installation
Kim, A. Culver, IN
10-31-2023
04/28/2022 Installation Of The Equipment Accepted In Proposal #BL413A
ILSE, M. CULVER, IN
08-08-2022
07/08/2022 Installation Of The Equipment Accepted In Proposal #BL487A TANKLESS WATER HEATER
DARREN, D. CULVER, IN
08-08-2022
Navien NPE-240A
04/28/2022 Installation Of The Equipment Accepted In Proposal #BL413A
ILSE, M. CULVER, IN
05-10-2022
04/05/2022 Navien 240 With Internal Recirculating Mount To Concrete Wall Existing Outlet Gas Need 15’ Csst And 2 Male Adapters Existing Manifold Built For Gas And 3/4” Existing Need Tee And Dirtleg Condensation Gravity To Sump Less Than 10’ Exhaust Out Top Of Wall Unit Hangs On But Keep It Towards Corner Where Sump Is For Future Addition Pull Intake From Basement Existing Pex Waters 3/4” Roll 220 Line From Water Heater And Disconnect Wire In Electrical Panel. Leave Everything Though For Future Dryer 25’ Of Csst From Furnace Closet Through Attic 7’ 6” Piece Of 1/2” Black To Hard Pipe Exposed On Back Of Chimney Drill Through To Fire Box For Gas Log Insert Leave Dirtleg On Outside Before Drilling Through Pin Tight To Brick Replace Softener In Basement Mount Whole House Filter To Concrete Wall Existing White 1” Pex Easy Peezy Navien 240 A Hang On Drywall Wall 2” Exhaust Only Approximately 15’ Total Condensation Pump Zip Tie Line To 1” Water Line And Dump Into Drain Furnace Is In Existing 1” Pex Bring Tees To Do 3/4” 1-1x1x3/4” Few 1” 90’s 10’ 1” White 1x3/4 Reducing Coupling Or Wring Crusher And Reuse Existing Remove Breaker For Water Heater And Install New Square D 20 Amp Breaker And Install Outlet Using Old Wire 3/4” Black Tee 3/4” Street 90 3/4x3/4x1/2 Tee 1/2” Valve 1/2” Plug 10’ 3/4” Csst 3/4” Tee Valve Dirtleg
LENA, G. CULVER, IN
04-08-2022
04/04/2022 Navien 240 With Internal Recirculating Mount To Concrete Wall Existing Outlet Gas Need 15’ Csst And 2 Male Adapters Existing Manifold Built For Gas And 3/4” Existing Need Tee And Dirtleg Condensation Gravity To Sump Less Than 10’ Exhaust Out Top Of Wall Unit Hangs On But Keep It Towards Corner Where Sump Is For Future Addition Pull Intake From Basement Existing Pex Waters 3/4” Roll 220 Line From Water Heater And Disconnect Wire In Electrical Panel. Leave Everything Though For Future Dryer 25’ Of Csst From Furnace Closet Through Attic 7’ 6” Piece Of 1/2” Black To Hard Pipe Exposed On Back Of Chimney Drill Through To Fire Box For Gas Log Insert Leave Dirtleg On Outside Before Drilling Through Pin Tight To Brick Replace Softener In Basement Mount Whole House Filter To Concrete Wall Existing White 1” Pex Easy Peezy Navien 240 A Hang On Drywall Wall 2” Exhaust Only Approximately 15’ Total Condensation Pump Zip Tie Line To 1” Water Line And Dump Into Drain Furnace Is In Existing 1” Pex Bring Tees To Do 3/4” 1-1x1x3/4” Few 1” 90’s 10’ 1” White 1x3/4 Reducing Coupling Or Wring Crusher And Reuse Existing Remove Breaker For Water Heater And Install New Square D 20 Amp Breaker And Install Outlet Using Old Wire 3/4” Black Tee 3/4” Street 90 3/4x3/4x1/2 Tee 1/2” Valve 1/2” Plug 10’ 3/4” Csst 3/4” Tee Valve Dirtleg
LENA, G. CULVER, IN
04-08-2022
03/02/2022 ESTIMATE TO REPLACE WATER HEATERS WITH NAVIEN TANKLESS. ALSO CHECK PIPE IN BASEMENT THAT LEAKS PERIODICALLY TO SEE IF IT CAN BE REPAIRED. WANTS TO HAVE TWO WASHERS AND DRYERS.
LENA, G. CULVER, IN
03-03-2022
08/24/2021 SEE ROUGH-IN ONLY AND TANKLESS CONTRACT
Brad, S. Culver, IN
12-21-2021
Navien NP-240A
06/02/21. INSTALLED NAVIEED TANKLESS WATER HEATER. NAVIEN 240 MODEL NPE-240A2-NG SERIAL 2087C2133161025
MARK, D. CULVER, IN
06-14-2021
09/30/2020....SWAPPED CUSTOMER SUPPLIED TANKLESS WATER HEATER
CHARLEY, M. CULVER, IN
01-08-2021
Navien NPE-240A
01/05/2021...INSTALLED NEW NAVIEN TANKLESS WATER HEATER
DAVID, R. CULVER, IN
01-05-2021
Call Justin Time for your hvac service!

©Red Barn Media Group 2024