Armstrong HVAC
4SHP20LX124P
Estimated for Modulating communicating WiFi 97% 20 seer high efficiency furnace and air conditioning.
Culver,
IN
01-12-2023
4SHP20LX124P
11/16/2022 Installation Of The Equipment Accepted In Proposal #BL565A HVAC-110,000 4 Ton Transition Approximately 24” Need New 10x25 One Piece With Duct Head And Will Need Transition Built Off Other End For Flex To Hook To See Pictures Will Need To Be 19” Wide By 25” Deep Will Need A 14x14 Return Grill For In The Drop Will Have To Pull Air From Closet Until Remodel Happens And Can Redo Duct Gravity Drain Will Need 40’ 2” And Concentric Go Out Through Garage And Outside Need New Box And Switch 5’ Conduit Gas Works Out Lineset 30’ Will Need 1 Piece Of Line Hide An Entry And 1 Coupling Will Need Ran Through Garage Also Existing Went Through Slab TANKLESS-Navien 240a2 Mount On Garage Wall Outside Closet 4” Boot Cap 10’ 3/4” Csst Will Need Dirtleg Valve And Adapters Outlet For Softener On Other Side Of Wall Need Box And Outlet Approximately 10’ Of 12 Gauge Existing Drain In Closet Will Need 10’ 3/4” Will Need To Run Exhaust Only Up On Ceiling Of Garage And Out Approximately 15’ Of 2” Existing 1/2” Copper Recirculating Line Will Need Ran To Navien Approximately 10’ Of 1/2” Copper Will Need 20’ 3/4” Copper And Propress Tools SOFTNER-Will Need 15’ 3/4” Copper Whole House Filter New 3/4” Full Port Valve Drain In Floor Possibly Clean It Out Existing Outlet Wanna MOVE SOFTENER BACK IN AS FAR AS POSSIBLE
CULVER, IN
11-28-2022
4SHP20LX124P
11/15/2022 Installation Of The Equipment Accepted In Proposal #BL565A HVAC-110,000 4 Ton Transition Approximately 24” Need New 10x25 One Piece With Duct Head And Will Need Transition Built Off Other End For Flex To Hook To See Pictures Will Need To Be 19” Wide By 25” Deep Will Need A 14x14 Return Grill For In The Drop Will Have To Pull Air From Closet Until Remodel Happens And Can Redo Duct Gravity Drain Will Need 40’ 2” And Concentric Go Out Through Garage And Outside Need New Box And Switch 5’ Conduit Gas Works Out Lineset 30’ Will Need 1 Piece Of Line Hide An Entry And 1 Coupling Will Need Ran Through Garage Also Existing Went Through Slab TANKLESS-Navien 240a2 Mount On Garage Wall Outside Closet 4” Boot Cap 10’ 3/4” Csst Will Need Dirtleg Valve And Adapters Outlet For Softener On Other Side Of Wall Need Box And Outlet Approximately 10’ Of 12 Gauge Existing Drain In Closet Will Need 10’ 3/4” Will Need To Run Exhaust Only Up On Ceiling Of Garage And Out Approximately 15’ Of 2” Existing 1/2” Copper Recirculating Line Will Need Ran To Navien Approximately 10’ Of 1/2” Copper Will Need 20’ 3/4” Copper And Propress Tools SOFTNER-Will Need 15’ 3/4” Copper Whole House Filter New 3/4” Full Port Valve Drain In Floor Possibly Clean It Out Existing Outlet Wanna MOVE SOFTENER BACK IN AS FAR AS POSSIBLE
CULVER, IN
11-28-2022
4SHP20LX124P
11/14/2022 Installation Of The Equipment Accepted In Proposal #BL565A HVAC-110,000 4 Ton Transition Approximately 24” Need New 10x25 One Piece With Duct Head And Will Need Transition Built Off Other End For Flex To Hook To See Pictures Will Need To Be 19” Wide By 25” Deep Will Need A 14x14 Return Grill For In The Drop Will Have To Pull Air From Closet Until Remodel Happens And Can Redo Duct Gravity Drain Will Need 40’ 2” And Concentric Go Out Through Garage And Outside Need New Box And Switch 5’ Conduit Gas Works Out Lineset 30’ Will Need 1 Piece Of Line Hide An Entry And 1 Coupling Will Need Ran Through Garage Also Existing Went Through Slab TANKLESS-Navien 240a2 Mount On Garage Wall Outside Closet 4” Boot Cap 10’ 3/4” Csst Will Need Dirtleg Valve And Adapters Outlet For Softener On Other Side Of Wall Need Box And Outlet Approximately 10’ Of 12 Gauge Existing Drain In Closet Will Need 10’ 3/4” Will Need To Run Exhaust Only Up On Ceiling Of Garage And Out Approximately 15’ Of 2” Existing 1/2” Copper Recirculating Line Will Need Ran To Navien Approximately 10’ Of 1/2” Copper Will Need 20’ 3/4” Copper And Propress Tools SOFTNER-Will Need 15’ 3/4” Copper Whole House Filter New 3/4” Full Port Valve Drain In Floor Possibly Clean It Out Existing Outlet Wanna MOVE SOFTENER BACK IN AS FAR AS POSSIBLE
CULVER, IN
11-28-2022
4SHP20LX124P
11/02/2022 Installation Of The Equipment Accepted In Proposal #BL558A
CULVER, IN
11-28-2022
4SHP20LX124P
09/20/2022 Installation Of The Equipment Accepted In Proposal #BL535A B Width 80% Down Flow 70,000 2.5 Ton Transition Return Plenum And Install Aprilaire Media Box 5” Metal Vent Bring Tin To Remove Humidifier And Patch Holes Gravity Drain Existing 3/4” Pvc Lineset 50’ Will Need To Remove Deck Boards And Probably Need To Use Fittings Due To Tough Feed Through Ceiling Space 40 Gallon Standard Vent With Existing Copper Will Need Poly Drain Pan And Hook Drain To Existing 3/4” Pvc May Need Reducer Most Pans Are 1” Bring Pro Press And Couple Dialectric Unions Leave Existing Thermostat
Culver, IN
10-13-2022
4SHP20LX124P
07/11/2022 ESTIMATED NEEDED FOR NEW HVAC SYSTEM
CULVER, IN
08-08-2022