Tankless hot water heaters from Justin Time Plumbing & Heating have become very popular in Culver, IN. Unlike conventional water tanks that make and store hot water 24 hours per day, tankless water heaters produce hot water as you are using it and shut down when you are done. A typical homeowner or business in Culver, IN can expect substantial energy savings. In addition, gas tankless units never run out of hot water so they are extremely convenient. Enjoy high efficiency, energy savings and endless hot water with a tankless system.

Get Your Quote Today



Justin Time Plumbing & Heating Gas Tankless Hot Water Heaters Culver, Indiana



Recent Gas Tankless Hot Water Heaters Culver, Indiana by Justin Time Plumbing & Heating

Gas Tankless Hot Water Heaters Culver, Indiana
04/28/2022 Installation Of The Equipment Accepted In Proposal #BL413A
CULVER, IN
08-08-2022

Gas Tankless Hot Water Heaters Culver, Indiana
07/08/2022 Installation Of The Equipment Accepted In Proposal #BL487A TANKLESS WATER HEATER
CULVER, IN
08-08-2022

Navien NPE-240A Gas Tankless Water Heater

04/28/2022 Installation of the equipment accepted in proposal #BL413A
CULVER, IN
05-10-2022

Navien NPE-240A Gas Tankless Water Heater

04/28/2022 Installation of the equipment accepted in proposal #BL413A
CULVER, IN
05-10-2022

NPE-240A
04/05/2022 Navien 240 With Internal Recirculating Mount To Concrete Wall Existing Outlet Gas Need 15’ Csst And 2 Male Adapters Existing Manifold Built For Gas And 3/4” Existing Need Tee And Dirtleg Condensation Gravity To Sump Less Than 10’ Exhaust Out Top Of Wall Unit Hangs On But Keep It Towards Corner Where Sump Is For Future Addition Pull Intake From Basement Existing Pex Waters 3/4” Roll 220 Line From Water Heater And Disconnect Wire In Electrical Panel. Leave Everything Though For Future Dryer 25’ Of Csst From Furnace Closet Through Attic 7’ 6” Piece Of 1/2” Black To Hard Pipe Exposed On Back Of Chimney Drill Through To Fire Box For Gas Log Insert Leave Dirtleg On Outside Before Drilling Through Pin Tight To Brick Replace Softener In Basement Mount Whole House Filter To Concrete Wall Existing White 1” Pex Easy Peezy Navien 240 A Hang On Drywall Wall 2” Exhaust Only Approximately 15’ Total Condensation Pump Zip Tie Line To 1” Water Line And Dump Into Drain Furnace Is In Existing 1” Pex Bring Tees To Do 3/4” 1-1x1x3/4” Few 1” 90’s 10’ 1” White 1x3/4 Reducing Coupling Or Wring Crusher And Reuse Existing Remove Breaker For Water Heater And Install New Square D 20 Amp Breaker And Install Outlet Using Old Wire 3/4” Black Tee 3/4” Street 90 3/4x3/4x1/2 Tee 1/2” Valve 1/2” Plug 10’ 3/4” Csst 3/4” Tee Valve Dirtleg

CULVER, IN
04-08-2022

NPE-240A
04/04/2022 Navien 240 With Internal Recirculating Mount To Concrete Wall Existing Outlet Gas Need 15’ Csst And 2 Male Adapters Existing Manifold Built For Gas And 3/4” Existing Need Tee And Dirtleg Condensation Gravity To Sump Less Than 10’ Exhaust Out Top Of Wall Unit Hangs On But Keep It Towards Corner Where Sump Is For Future Addition Pull Intake From Basement Existing Pex Waters 3/4” Roll 220 Line From Water Heater And Disconnect Wire In Electrical Panel. Leave Everything Though For Future Dryer 25’ Of Csst From Furnace Closet Through Attic 7’ 6” Piece Of 1/2” Black To Hard Pipe Exposed On Back Of Chimney Drill Through To Fire Box For Gas Log Insert Leave Dirtleg On Outside Before Drilling Through Pin Tight To Brick Replace Softener In Basement Mount Whole House Filter To Concrete Wall Existing White 1” Pex Easy Peezy Navien 240 A Hang On Drywall Wall 2” Exhaust Only Approximately 15’ Total Condensation Pump Zip Tie Line To 1” Water Line And Dump Into Drain Furnace Is In Existing 1” Pex Bring Tees To Do 3/4” 1-1x1x3/4” Few 1” 90’s 10’ 1” White 1x3/4 Reducing Coupling Or Wring Crusher And Reuse Existing Remove Breaker For Water Heater And Install New Square D 20 Amp Breaker And Install Outlet Using Old Wire 3/4” Black Tee 3/4” Street 90 3/4x3/4x1/2 Tee 1/2” Valve 1/2” Plug 10’ 3/4” Csst 3/4” Tee Valve Dirtleg

CULVER, IN
04-08-2022

NPE-240A
03/02/2022 ESTIMATE TO REPLACE WATER HEATERS WITH NAVIEN TANKLESS. ALSO CHECK PIPE IN BASEMENT THAT LEAKS PERIODICALLY TO SEE IF IT CAN BE REPAIRED. WANTS TO HAVE TWO WASHERS AND DRYERS.

CULVER, IN
03-03-2022

NPE-240A
08/24/2021 SEE ROUGH-IN ONLY AND TANKLESS CONTRACT

Culver, IN
12-21-2021

Navien NP-240A Hi-Temp Condensing Tankless Water Heater W/ Circ

06/02/21. INSTALLED NAVIEED TANKLESS WATER HEATER. NAVIEN 240 MODEL NPE-240A2-NG SERIAL 2087C2133161025
CULVER, IN
06-14-2021

Navien NP-240A Hi-Temp Condensing Tankless Water Heater W/ Circ

06/02/21. INSTALLED NAVIEED TANKLESS WATER HEATER. NAVIEN 240 MODEL NPE-240A2-NG SERIAL 2087C2133161025
CULVER, IN
06-14-2021

Navien NPE-240A Gas Tankless Water Heater

01/05/2021...INSTALLED NEW NAVIEN TANKLESS WATER HEATER
CULVER, IN
01-05-2021